Rice Lake SCT2200-AN Analog Output Advanced Series Signal Conditioning Weight Transmitter
For PLC systems that require weight data from a scale, Rice Lake’s compact SCT transmitters deliver equivalent signal-conditioning function without the cost or bulk of a full size weight indicator/controller. Rice Lake's SCT2200 is DIN Rail mountable within a cabinet or control panel, where it converts a scale’s load cell signals to analog output, serial output, or a specific network protocol. Unlike many other signal transmitters, the SCT2200 has its own 0.3 inch weight display, with annunciators for unit and weighing status, and push buttons for zero, tare and setpoint entry, simplifying scale setup, calibration and operation.
Features
- Analog output
- HUB Mode connects up to 16 transmitters to one fieldbus
- Quick menu for real and theoretical calibration
- Web browser weight monitoring and calibration over EtherNet/ IP, Profinet and Modbus TCP network
- Red LED display with six-digits (8 mm) and six LEDs show active functions
- Standard DIN rail- mounting with power supply and enclosures
- Configurable calibration and setup parameters from keyboard
- Up to three calibration linearization points or three from the keyboard
- Reading of the net, gross and tare weights, clearing, semi-automatic and presettable tare, scale switch, setting of outputs application thresholds
- Diagnostic information via serial port, message display, printing, setting of APW in counting mode, simulation of key pressure, Modbus RTU
- Double RS-485 port for a quick network connection
- Printer management on second serial port available
- Multi-range function allows for subdividing the scale capacity in two, each up to 3,000 divisions
- Maximum Displayed Resolution:
- 1:800,999
- Internal Resolution:
- 1.5 million counts
- Weighing Units:
- lb, kg, g
- Display:
- LED
- Keypad Controls:
- 5 tactile switches
- Digital Inputs:
- 2 inputs - 12/24 VDC
- Outputs:
- 2 outputs - 150 mA 48 VAC/ 150 mA 60 VDC
- NEMA Rating:
- NEMA Type 1 plastic pluggable connectors
- Load Cell Excitation:
- 5 VDC, 120 mA
- Load Cell Drive:
- Up to 8 x 350 ohm
- Analog Load Cell Input Range:
- +/- 39 mV
- Analog Load Cell Signal Sensitivity:
- 0.03 μV/graduation minimum, 0.3 μV/grad recommended
- A/D sample rate:
- 80 Hz
- Communication:
- RS-485 or RS-232
- Operating Temperature Range:
- -10°F to 50°F / 14°C to 122°C
- Power:
- 12-24 VDC, 5 watts
- Dimensions:
- 0.98 x 4.52 x 4.72 in
- Weight:
- 1 lb
- Brand:
- Rice Lake
- Model:
- SCT2200-AN