null Skip to main content
Our offices will be closed 12/23-12/25 for Christmas.

Rice Lake SCT20-DN Configurable Signal Conditioning Transmitter

MSRP: $675.00
$641.00
(Save $34.00)
Part #:
129397
Availability:
Typically ships in 1-2 days

For PLC systems that require weight data from a scale, Rice Lake’s compact SCT-20 transmitter delivers equivalent signal-conditioning function without the cost or bulk of a full size weight indicator/controller. The Rice Lake SCT-20 is DIN-rail mountable within a cabinet or control panel, where it converts a scale’s load cell signals to analog output, serial output, or a specific network protocol. Unlike many other signal transmitters, Rice Lake’s SCT-20 has its own .3 inch weight display, with annunciators for unit and weighing status, and push buttons for zero, tare and setpoint entry.  This significantly simplifies scale setup, calibration and operation.

Features

  • Converts digital weight to DeviceNet™ output
  • Space saving DIN rail mounting
  • 999,999 displayed resolution
  • Internal resolution 16 million counts
  • System linearity ± 0.01% full scale
  • Supports up to 8 350 ohm load cells
  • Serial port RS-485 or RS-232 simplex supports up to 115,200 bps
  • 2 inputs, 3 outputs
  • LED display, 0.3 in, six digit, seven segment
  • NEMA Type 1 plastic pluggable connectors
  • Display units in lb, kg, and grams
  • Center of zero, motion, net, and units annunciators
  • 4 Keys for zero, tare, menu, escape, left and up navigation, enter
  • 12-24 VDC power

Documentation

Rice Lake SCT-20 Data Sheet Rice Lake SCT-20 Manual

1 year manufacturer's limited warranty
Signal Output:
DeviceNet¢€ž¢
Maximum Displayed Resolution:
1:999,999
Internal Resolution:
16 million counts
Weighing Units:
lb, kg, g
Display:
LED
Keypad Controls:
4 tactile switches
Digital Inputs:
2 inputs 5-24 VDC
Outputs:
3 outputs 115 VAC/150mA N.0. or N.C. (dry contact)
NEMA Rating:
NEMA Type 1 plastic pluggable connectors
Load Cell Excitation:
5 VDC, 120 mA
Load Cell Drive:
Up to 8 x 350 ohm
Analog Load Cell Input Range:
+/- 39 mV
Analog Load Cell Signal Sensitivity:
0.1 μV/graduation minimum, 1.0 μV/grad recommended
A/D sample rate:
300 Hz
Communication:
RS-485 or RS-232 simplex supports up to 115,200 bps
Operating Temperature Range:
-4°F to 140°F / -20°C to 60°C
Power:
12-24 VDC, 5 watts
Housing Dimensions:
0.98 x 4.52 x 4.72 in
Weight:
1 lb
Brand:
Rice Lake
Model:
SCT20-DN

Related Products

Why Scales Plus?

Subscribe to our newsletter

Get the latest updates on new products and upcoming sales