Rice Lake RL75040-50KLE 50,000lb Double Ended Beam Load Cell

The Rice Lake RL75040 double ended beam load cells are designed for center mounting and double link loading. The RL75040 is most commonly used in truck scale applications. The RL75040 is compatible with Unilink/Translink suspension up to 75,000 lb. The RL75040 series load cells come with a 35 ft load cell cable and are constructed of alloy steel with nickle plating. The RL75040 is NTEP approved Class III 1:10,000 for legal for trade applications.

RL75040 load cells are used in the following Rice Lake Weighing module kit: Translink. The RL75040 load cells are interchangeable with VPG Sensortronics 65040A, Artech 80310, Thurman TSC 840, and VPG Celtron DLB load cells.

Features

  • 50,000 lb capacity rating
  • NTEP approved Class III 1:10,000
  • Large Envelope
  • Stainless steel construction
  • Environmentally sealed IP 67 rating
  • 3 mV/V output
  • Load cell cable length 35 ft
  • 2 year limited manufacturer's warranty
  • Safe overload up to 150% capacity
  • Safe sideload up to 100% capacity
2 year limited manufacturer's warranty
Manufacturer:
Rice Lake Weighing Systems
Model:
RL75040-50K
Part Number:
21616
Certification:
NTEP certified Class III 1:10,000
Other Approvals:
cFM, CE
Capacity Rating:
50,000 lb / 22,215.5 kg
Safe Overload:
150% capacity
Safe Side Load:
100 % capacity
Length:
11.5"
Width:
1.94"
Height:
2.94"
Conduit adapter:
1/2 14 NTP
Construction / Finish:
Alloy steel, nickle plating
Cable Color Code:
Red = + Excitation, Black = - Excitation, Green = + Signal, White = - Signal
Rated Excitation:
5-10 VDC (maximum of 15 V)
Full Scale Output:
3.0 mV/V
Output Resistance:
700 (± 5) ohms
Input Resistance:
770 (± 10) ohms
Insulation Resistance:
1000 megohms
Nonlinearity:
0.03% full scale
Hysteresis:
0.02% full scale
Operating Temperature Range:
-40°F to 150°F / -40°C to 65°C
Compensated Temperature Range:
14°F to 104°F / -10°C to 40°C
Seal Type:
IP67 Environmentally Sealed
Cable Length:
35 ft
Cable Diameter:
0.305 polyurethane jacket
Interchangeable Products:
VPG Sensortronics 65040A, Artech 80310, Thurman TSC 840, and VPG Celtron DLB load cells