Rice Lake RL75016SS-W-50K 50,000lb Stainless Steel Double Ended Beam Load Cell
The Rice Lake RL75016SS-W double ended beam load cells are designed with center loading which is most commonly used in applications such as tank, hopper, and truck scales. The RL75016SS-W series load cells have a non threaded hole, come with a 25 ft load cell cable, and are constructed of stainless steel.
RL75016SS-W load cells are used in the following Rice Lake Weighing module kit: RL1600 Series. The RL75016SS-W load cells are interchangeable with Rice Lake Weighing Systems RL75016SS and VPG Celtron DSR-HSS load cells.
Features
- 50,000 lb capacity rating
- Stainless steel construction
- Welded seal IP 67 rating
- 3 mV/V output
- Load cell cable length 25 ft
- 2 year limited manufacturer's warranty
- Safe overload up to 150% capacity
- Safe sideload up to 100% capacity
- Load cell is not NTEP approved for legal for trade applications
- Manufacturer:
- Rice Lake Weighing Systems
- Model:
- RL75016SS-W-50K
- Part Number:
- 168120
- Certification:
- Not NTEP certified
- Capacity Rating:
- 50,000 lb / 22,679.6 kg
- Safe Overload:
- 100% capacity
- Length:
- 13.5"
- Width:
- 2.44"
- Height:
- 2.94"
- Conduit adapter:
- 1/2 14 NTP
- Hole Threading:
- thru hole
- Construction / Finish:
- Stainless steel
- Cable Color Code:
- Red = + Excitation, Black = - Excitation, Green = + Signal, White = - Signal
- Rated Excitation:
- 5-10 VDC (maximum of 15 V)
- Full Scale Output:
- 3.0 mV/V
- Output Resistance:
- 700 (± 5) ohms
- Input Resistance:
- 770 (± 10) ohms
- Insulation Resistance:
- 5000 megohms
- Nonlinearity:
- 0.03% full scale
- Hysteresis:
- 0.02% full scale
- Operating Temperature Range:
- -40° F to 150° F / -40°C to 65°C
- Seal Type:
- IP67 Welded Seal
- Cable Length:
- 25 ft
- Cable Diameter:
- 0.2 polyurethane jacket
- Interchangeable Products:
- Rice Lake Weighing Systems RL75016SS and VPG Celtron DSR-HSS load cells