Doran 8100IS indicators meets the latest UL testing standards for intrinsically safe equipment. 8100IS indicators are IP6X certified against hazardous dust and fine particles that are susceptible to ignition. Pair with FM approved load cells and junction boxes to create an intrinsically safe scale system.
Features
- UL Certified intrinsically safe indicator for use in hazardous locations
- IP6X environmental protection
- Data output via fiber optic to RS232 converter to safe area RS-232 printers or data collection software
- Two remote switch inputs
- Responsive user interface that is easy to operate
- Large backlit display is easy to read in all lighting conditions
Service Note
- Power supply is not included with purchase of 8100IS
- Power indicator with either PN: 8AIS AC power supply or PN: 8BIS rechargeable battery
Intrinsic Safety
- Class I, Div 1, Groups A,B,C,D
- Class II, Div 1, Groups E,F,G
- Class III, Div. 1
- Zone 0, Group IIC
- Zone 20, Group IIIC
Applications
- General weighing
Documentation
Doran 8100IS Data Sheet Doran 8100IS Manual Doran 8100IS Installation Diagram
- UL Certificate #:
- 20190304-E485121
- Hazardous Area Approval Ratings:
- Class I, Div 1, Groups A,B,C,D / Class II, Div 1, Groups E,F,G / Class III, Div. 1 / Zone 0, Group IIC / Zone 20, Group IIIC
- NTEP:
- Yes
- Class:
- III
- CC:
- 06-101A2
- Resolution Range:
- 200d to 100,000 d
- Load Cell Capability:
- Up to four 350 Ohm load cells
- Units:
- lb, kg, oz, g, lb:oz
- Load Cell Excitation:
- 5 VDC
- System Linearity:
- 0.01% full scale
- Wiring Style:
- Hard Wire
- Power:
- None Included Standard, will require PN: 8BIS or PN: 8AIS to power
- IP Rating:
- IP6X
- Enclosure Construction:
- 304 stainless steel
- Buttons:
- Tare, Gross / Net, Zero, Print, Units
- Display Type:
- LCD
- Standard Communication:
- Fiber optic to RS232 converter
- Digital I/O:
- Two remote switch inputs
- Brand:
- Doran
- Part Number:
- 8100IS