Cardinal Detecto 185B Rival Digital Indicator, NTEP
The Cardinal Detecto 185 Rival indicator is an economical yet effective solution for an indicator. The extremely visible display makes it a great fit for busy shipping and receiving areas. The IP66 rated ABS plastic design allows the 185 to be utilized in quite difficult environments such as food service or industrial manufacturing. The 185 is even capable of counting so it can be paired with a bench scale or floor scale for packaging and parts counting. The Rival is NTEP approved for use in legal for trade applications. The Cardinal 185B can be operated with an AC adapter, six AA alkaline batteries, or Ni-Cad or NiMH batteries.
- NTEP approved 18-075
- Measurement Canada AM-6109
- OIML certificate number R-76/2006-A-DK2-18.0
- Operated with an AC adapter, six AA alkaline batteries, or Ni-Cad or NiMH batteries, batteries not included
- IP66-rated ABS indicator enclosure with versatile stainless steel wall or desktop mounting bracket
- Bold 1-inch/25-mm high backlit LCD
- Resolution of 6000 divisions approved
- Internal resolution of 1 part in 16,777,216
- Division values of 1, 2 or 5 x 10, 1, 0.1, 0.01, 0.001
- Simple 7 button operation ON/OFF, ZERO, TARE, NET/GROSS, UNITS, FN, PRINT
- Bi-directional RS-232, standard 9 pin connector
- Audit trail for NTEP and OIML requirements
- Zero tracking
- Push button tare up to 100% capacity
- Runs up to four 350 ohm load cells
- Units include lbs, kg, grams, and ounces
Applications
- General Weighing
- Counting
- Food Service
- Warehousing
- Shipping and Receiving
- Manufacturer:
- Detecto
- Model:
- 185B
- NTEP:
- Yes
- NTEP CC:
- 18-075
- NTEP Class:
- III 1:6000
- Indicator Construction:
- IP66-rated ABS indicator enclosure
- Display:
- Bold 1-inch/25-mm high backlit LCD
- Operating Temperature:
- 14°F to 104°F
- Power Source:
- AC adapter, six AA alkaline batteries, or Ni-Cad or NiMH batteries, batteries not included
- Communication:
- Bi-directional RS-232
- Dimensions:
- 7.7 in W x 4.7 in H x 2.6 in D
- Keys:
- 7 button operation ON/OFF, ZERO, TARE, NET/GROSS, UNITS, FN, PRINT
- Load Cell Capability:
- Up to four 350 ohm load cells